Figure 2 - 1691 Dimensions (all versions) and Mounting Specifications
INSTALLATION 1691
2
Installation
This installation should be made by qualified service personnel
and should conform to all local codes. Safeguards must be
taken to avoid unintentional operation by employees, janitors,
and cleaners working about the premises, by falling objects, by
customers, by building vibration, and by similar causes.
Mounting
The 1691 Code Distributors are designed for indoor use only.
The units may be surface mounted via the mounting openings
on each side of the 1691 housing (total of four mounting
openings).
The overall dimensions for all versions of the 1691 unit are as
follows (see Figure 2):
Height (top to bottom): 12” (305mm)
Width (side to side): 14” (356mm)
Depth (front to back): 4” (102mm)
Mounting Surfaces
Mount all versions of the 1691 with 1/4-inch diameter bolts
appropriate to the type of mounting surface.
Wood Surfaces
For mounting to wood studs, use lag bolts (with a drilled
pilot hole) or wood screws which penetrate the wood for
at least one and a half inches (1.5”).
Concrete Surfaces
In concrete, use lead or plastic anchor expansion bolts
with a minimum pull-out rating of 25 pounds.
Steel Surfaces
For steel surfaces, drill four clearance holes and use bolts
with lockwashers and nuts.
Drywall Surfaces
For drywall (gypsum) surfaces, use toggle bolts. Note that
the drywall surface must be at least 3/8”.