American Dynamics AD1273 Manuel d'installation Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
CONNECTIONS AD1273
10
CONNECTIONS
Data Line Connections
Data line connections to the AD1273 are made with user-
supplied, 2-wire twisted pair, shielded, Belden 8760 or
equivalent (Plenum 88760). The maximum data line length is
5000 feet (1524m).
Data lines enter the AD1273 through a 7-pin Plug and Ramp
connector unit (see Figure 8). The 7-pin Ramp connector is
attached to the AD1273 printed circuit board. The 7-pin Plug
mating connector is shipped with the AD1273 unit.
Assemble the 7-pin Plug connector by inserting the appropriate
data lines into the corresponding pin slots listed in Table 4 and
tightening the hold-down screws. Table 4 - Data Line Connections to 7-Pin Plug Connector
Pin 1 - Data line SHIELD (S)
Pin 6 - Data line WHITE (W) wire
Pin 7 - Data line BLACK (B) wire
Figure 8 - Data Line Connections
1
2
3
4
5
6
7
7-Pin Plug Connector
1
2
3
4
5
6
7
W
B
S
Data Lines
7-Pin Ramp Connector
(Mounted to Circuit Board)
PCB Cover
Vue de la page 15