American Dynamics RAS917LS-1 Manuel de l'opérateur Page 54

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 130
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 53
Figure 4–6: Left and Right Scan Limits
Left Scan
Limit
Parking
Lot
Building
Dome
Right Scan
Limit
Scan Types
Three types of scans may be activated: smooth scan, stepped scan, and random scan.
A smooth scan slowly pans between the left and right scan limits, starting at the left scan limit. When
the right scan limit is reached, the scan reverses. Figure 4–6 illustrates the smooth scan.
A stepped scan pans slowly, pausing briefly every 10° between the left and right scan limits. Once
the right scan limit is reached, the scan reverses. Figure 4–7 illustrates the stepped scan. Each
arrowhead represents a 10° step in the scan.
Figure 4–7: Stepped Scan
Left Scan
Limit
Parking
Lot
Building
Dome
Right Scan
Limit
4–18 SpeedDome Ultra VII Day/Night Operator's Manual