RAID
62 Intellex®
Array Degraded Status
1 Exit the Intellex application and go to the Windows desktop.
2 At the Windows desktop, click Start > Programs > 3ware > 3DM2 > 3DM 2 Web Interface.
3 Go to Login, choose login as Administrator, and type the password 3ware.
4 Click Information > Drive Information on the top navigation bar.
5 A list of drives and their status displays. Check which drive has failed.
6 Check all connections to the drive and refresh the 3DM2 page. If the drive is still degraded,
follow the on-screen recommendation. Use the Help button to access the 3DM2 utility online
help. If called for, follow drive installation procedures given earlier in this chapter.
7 Record the hard drive's number for future reference.
8 Close the 3DM2 utility and restart the Intellex application. The array begins rebuilding during
normal Intellex operation.
During rebuilding, you can still read and write data to the array. However, fault tolerance is lost until
the array is restored to Functional status.
Note
When rebuilding is complete, the status of the drive will change from Degraded to OK in the 3DM2
utility.
Recovering RMS Offline Array to Functional System
Recreating the RAID-5 array is necessary if the array status goes offline when 2 or more hard
drives fail or another system failure causes the array to fail.
Checking the Array Status
1 Shut down and restart the system.
2 At the Windows desktop, click Start > Programs > 3ware > 3DM2 > 3DM 2 Web Interface.
3 Go to Login, choose login as Administrator, and type the password 3ware.
4 Click Information > Drive Information on the top navigation bar.
5 A list of drives and their status displays. Check which drive has failed.
Checking the Status of the Array in BIOS
1 Shut down and restart the system.
2 Press [Alt]+3 to enter the 3ware Bios manager screen.
3 View the Exportable Units list to observe the hard drive responsible for the degraded array.
Offline Array
If the array status is Offline:
1 At the Windows desktop, click Start > Programs > 3ware > 3DM2 > 3DM 2 Web Interface.
2 Go to Login, choose login as Administrator, and type the password 3ware.
3 Click the Help button on the utility screen and follow the help procedures.