Matrix Installation and Operation
Alarm Input Connections
Each model of MegaPower LT has the same number of alarm inputs as camera inputs.
The alarm inputs are located on removable five way-terminal blocks, with each plug holding
four alarm input connections and one ground connection. The MPLT senses physically
connected alarms (via dry contacts). These inputs can be individually configured in the
menu system as normally-open or normally-closed contacts.
To connect alarm inputs:
1. Remove the required five-way terminal block.
2. Connect each terminal to an alarm relay, with connections made as labelled in the
diagram below:
3. Group the returns and lead them into the ground connection.
4. Return the five-way terminal block to its position on the MegaPower LT.
In the menu system, the alarm input connections are normally-closed by default. If
connecting normally-open alarms, ensure that the alarm input sense is re-configured in
the menu system (see page 34).
Auxiliary Output Connections
MegaPower LT 16x4 models have one auxiliary output and MegaPower LT 32x8 models
have two. To connect an auxiliary output, remove the three-way terminal block and connect
alarm or auxiliary equipment in one of the relay configurations shown below:
The auxiliary output will operate in the rest state until it is triggered, at which point it will
switch to the active state. Once connected, an auxiliary output can be added to alarm
responses in the menu system so that when an alarm or event occurs, the auxiliary output
will switch to the active state (see page 35).