28
MegaPower LT
Specifying Alarm Monitors
The Alarm Monitor screen is used to set which monitors will display triggered alarms.
To specify alarm monitors, follow the steps below:
1. In the Alarm menu, select the Alarm Monitors option.
2. In the Alarm Monitor screen, use up/down joystick commands to move to the monitor
that is to be used to display alarms.
3. Using the right joystick command, select DISPLAY to display alarms on this monitor
(or NO DISPLAY to not).
4. Repeat steps 2 and 3 to set all monitors as required.
5. Once selections on this screen are complete, select the Return to Alarm Menu to
return to the previous menu.
Configuring Alarm Inputs
Using the Alarm Input Sense screen, it is possible to configure each connected alarm
input as either a normally-open contact (N/O) or a normally-closed contact (N/C). This is
useful when working with different types of alarm detectors.
5.4 Alarm Monitors
Monitor 1 :DISPLAY
Monitor 2 :NO DISPLAY
Monitor 3 :NO DISPLAY
Monitor 4 :NO DISPLAY
Monitor 5 :NO DISPLAY
Monitor 6 :NO DISPLAY
Monitor 7 :NO DISPLAY
Monitor 8 :NO DISPLAY
Return to Alarm Menu
5.5 Alarm Input Sense
Alarm Number 01:N/C
02:N/O
03:N/O
04:N/O
05:N/O
06:N/O
07:N/O
08:N/O
Return to Alarm Menu